Nano-Imaging

Loading

Inverted Confocal Laser Scanning Microscope (CLSM FV1000)

Brand : Olympus
Model : FV1000
Location : B200 Room, 2nd Floor, B Building, Phyathai Campus
Custodian : Wattapong Pinyo

Service Fee :

SC staff

Mahidol

Government

Private

1,000

1,700

2,200

3,300

Description and Specification :

FV1000 LASER

ExcitationSuitable Dyes
405nmAlexa 405, DAPI, Hoechst
458nmCFP
488nmAlexa 488, FITC, GFP, Cy2
515nmAlexa 514, YFP
543nmAlexa 546, Alexa 568, TRITC, Cy3, DiI, Propidium Iodide, Texas red , mCherry
633nm

Alexa 633, Alexa 647, Cy5

Epifluorescence

Fluorescence can be observed on through IX-81 using the mercury lamp and filter cubes. We currently have 3 filter cubes installed.

DAPI (Hoechst): ex 335-375, em 440-500
FITC (EGFP/Alexa 488): ex 465-495, em 515-555
TRITC (Alexa 546, Alexa 568, Alexa 633, Topro-3): ex 515-550, em 600-640

Objective lens :

10x air – UPlanSApo  – NA 0.40
20x air – UPlanSApo  – NA 0.75
40x air – UPlanSApo  – NA 0.90 – with correction collar
60x oil – PlanSApo N – NA 1.42

Detector : Photomultiplier tube (PMT)

Sample Type:

• glass slide with cover slip

• well plate (only 10x len)

Live Cell Fluorescence Imaging System (IX83)

Brand : Olympus
Model : IX83
Location : B200 Room, 2nd Floor, B Building, Phyathai Campus
Custodian : Wattapong Pinyo

Service Fee :

SC staff

Mahidol

Government

Private

100

250

350

500

Description and Specification :

A dedicated live-cell imaging microscope in multiple channels (both fluorescence and brightfield, including phase contrast and DIC with temperature, 5% CO2, humidity control) over long time periods (xyzt in multiple channels).

3 filter cubes installed.

DAPI (Hoechst): ex 335-375, em 440-500
FITC (EGFP/Alexa 488): ex 465-495, em 515-555
TRITC (Alexa 546, Alexa 568, Alexa 633, Topro-3): ex 515-550, em 600-640

Objective lens :

• 4x air – UPlanFL N  – NA 0.13
• 10x air – UPlanFL N – NA 0.30
• 20x air – LUCPlanFL N – NA 0.45 – with correction collar
20x air – UCPlanFL N – NA 0.70 – with correction collar
40x air – LUCPlanFL N – NA 0.60 – with correction collar
60x air – LUCPlanFL N – NA 0.70 – with correction collar

Detector : DP74

Sample Type:

• glass slide with cover slip

• well plate

Fluorescence Microscope (BX53)

Brand : Olympus
Model : BX53
Location : B200 Room, 2nd Floor, B Building, Phyathai Campus
Custodian : Wattapong Pinyo

Service Fee :

SC staff

Mahidol

Government

Private

20

50

100

300

Description and Specification :

4 filter cubes installed.

Filter No.

Unit Name

Excitation Filter

Emission Filter

Dichromatic Mirror

1

U-FBNA Blue Excitations

470 – 495

510 – 550

505

2

U-FBW Blue Excitations

460 – 495

510IF

505

3

U-FGW Green Excitations

530 – 550

575IF

570

4

U-FUW Ultraviolet Excitations

340 – 390

420IF

410

Objective lens :

• 2x air – PlanApo N  – NA 0.08
• 4x air – UPlanFL N – NA 0.13
• 10x air – UPlanFL N – NA 0.30
20x air – UPlanFL N – NA 0.50
40x air – UPlanFL N – NA 0.75
60x oil – PlanApo N – NA 1.42
100x oil – UPlanFL N – NA 1.30

Detector : DP74

Sample Type:

• glass slide with cover slip

Macro Zoom Imaging System (MVX10)

Brand : Olympus
Model : MVX10
Location : B200 Room, 2nd Floor, B Building, Phyathai Campus
Custodian : Wattapong Pinyo

Service Fee :

SC staff

Mahidol

Government

Private

100

250

350

500

Description and Specification :

2 filter cubes installed.

Filter No.

Unit Name

Excitation Filter

Emission Filter

Dichromatic Mirror

1

U-MGFPHQ

460-480HQ

495-540HQ

485

2

U-MRFPHQ

535-555HQ

570-625HQ

565

Objective lens :

• 1x 
• 2x 

Seamless zoom observation from 6.3x to 126x

Detector : DP80

Sample Type:

• glass slide with cover slip

• well plate

Field Emission Scanning Electron Microscopy (FESEM SU-8010)

Brand : Hitachi
Model : SU8010
Location : B200 Room, 2nd Floor, B Building, Phyathai Campus
Custodian : Wattapong Pinyo

Service Fee :

SC staff

Mahidol

Government

Private

800

1,500

2,000

2,700

EDX (Baht/File) :

SC staff

Mahidol

Government

Private

200

400

500

500

Description and Specification :

• Ultra high resolution imaging (Resolution 1.0nm/15kV)

• Beam deceleration function as standard (Resolution 1.3nm/1kV)

• SE-BSE signal mixing function (Super ExB)

Secondary Electron

Image Resolution

1.0 nm (Vacc 15 kV, WD=4 mm)

1.3 nm (landing voltage 1kV, WD=1.5 mm)

Low mag mode

20-2,000 ×

High mag mode

100-800,000 ×

Electron gun

Cold cathode fi eld emission source

Accelerating voltage

0.5 kV to 30 kV(Standard mode)

Landing voltage

0.1 kV to 2.0 kV(Deceleration mode)

Lens system

3-stage electromagnetic lens reduction system

Objective lens aperture

Objective aperture(Heating type), 4 openings selectable from outside of vacuum, fi nely adjustable

Max. sample size

100 mm dia.

Ion Sputter (E102)

Brand : Hitachi
Model : E102
Location : B200 Room, 2nd Floor, B Building, Phyathai Campus
Custodian : Wattapong Pinyo

Service Fee :

SC staff

Mahidol

Government

Private

300

450

600

900

Description and Specification :

Target : Platinum

Critical Point Dryer (HCP-2)

Brand : Hitachi
Model : HCP-2
Location : B200 Room, 2nd Floor, B Building, Phyathai Campus
Custodian : Wattapong Pinyo

Service Fee :

SC staff

Mahidol

Government

Private

200

300

400

600

 

Ultra Microtome (UC6)

Brand : Leica
Model : EM UC6
Location : B200 Room, 2nd Floor, B Building, Phyathai Campus
Custodian : Wattapong Pinyo

Service Fee :

SC staff

Mahidol

Government

Private

50

100

200

300

Description and Specification :